"name": "rungstone",
"version": "0.1.7",
"description": "Offline, read-only toolkit for controls engineers: understand, translate, verify and dependency-map PLC code across Rockwell, Siemens, CODESYS and Beckhoff; extend to HMI/SCADA screens, tags and alarms; troubleshoot stops from exported historian data. Safety-rated logic is always excluded; simulation results are labelled simulated, not hardware-tested.",
"author": {
"name": "Arun Venkatadri"
},
"homepage": "https://github.com/arunvenkatadri/rungstone",
"repository": "https://github.com/arunvenkatadri/rungstone",
"license": "MIT",
"keywords": [
"plc",
"ladder-logic",
"structured-text",
"rockwell",
"siemens",
"tia-portal",
"codesys",
"twincat",
"plcopen",
"scada",
"hmi",
"industrial-automation",
"migration",
"alarm-management"
],
"skills": "./skills/",
"interface": {
"displayName": "Rungstone",
"shortDescription": "PLC, HMI and trip analysis",
"longDescription": "Rungstone helps industrial controls engineers work with PLC, HMI/SCADA and historian exports.\n\n- Understand PLC code: a plain-English summary, the machine sequence by rung, and a signal table where every meaning is labelled confirmed, from comment, from I/O map, inferred or unknown.\n- Translate between Rockwell Logix, SLC 500, Siemens S7-1500 SCL, IEC 61131-3 Structured Text, OpenPLC / Beremiz and IEC 61499 (Eclipse 4diac), with a mapping table and a ranked review queue the engineer approves before export.\n- Verify translations in a scan-cycle simulator (results are labelled simulated, not hardware-tested).\n- Lock-in report for CODESYS and TwinCAT projects: what ties the code to its platform, rated per target with rough hours.\n- Check (static analysis for likely bugs), diff two exports of the same project in plain English, and generate unit tests (CfUnit, TcUnit or plain IEC) from the code's current behaviour.\n- Map readers, writers and conflicts across PLC and HMI/SCADA, retarget HMI tags, and clean up alarms.\n- Find why a line or pump stopped from historian and alarm exports, and cite the PLC rung that caused it.\n\nRead-only by design: it never connects to or writes to a controller, excludes safety-rated logic with a visible notice, and never opens source-protected code. Not for use on a production system without review and testing by a qualified engineer. Provided as is, without warranty.",
"developerName": "Arun Venkatadri",
"category": "Developer Tools",
"capabilities": [
"Read",
"Write"
],
"websiteURL": "https://github.com/arunvenkatadri/rungstone",
"supportURL": "https://github.com/arunvenkatadri/rungstone/issues",
"privacyPolicyURL": "https://github.com/arunvenkatadri/rungstone/blob/main/PRIVACY.md",
"termsOfServiceURL": "https://github.com/arunvenkatadri/rungstone/blob/main/LICENSE",
"defaultPrompt": [
"Explain what this L5X does, rung by rung",
"Translate this SLC 500 ladder to Siemens S7-1500 SCL",
"Why did the pump trip? The historian and alarm exports are in this folder"
],