← Files Rapid Engineering SupportARCHIVED FILE

plugin.json

7.8 KB · Nov 17, 2026 · 00:11 UTC

↓ Download file

{
  "$schema": "https://agent-plugins.org/schemas/1.0.0/plugin.schema.json",
  "name": "rapid-engineering-support",
  "version": "1.0.1",
  "description": "Connect authorized engineering references and certified calculations to ChatGPT through Rapid Integrated Solutions.",
  "author": {
    "name": "Rapid Integrated Solutions",
    "email": "chad@ris-us.com",
    "url": "https://www.ris-us.com"
  },
  "homepage": "https://www.ris-us.com/rapid-engineering-support",
  "keywords": [
    "engineering",
    "technical reference",
    "engineering calculations",
    "reference library",
    "estimating"
  ],
  "extensions": {
    "com.openai": {
      "interface": {
        "displayName": "Rapid Engineering Support",
        "shortDescription": "Engineering reference tools",
        "longDescription": "Find information in authorized engineering reference libraries and use RIS-certified calculation tools from ChatGPT. Search approved reference filenames and folders, retrieve bounded text excerpts, inspect authorized workbook formulas in read-only ranges, and run the supported ASCE 7-05 simplified wind calculation with declared inputs. Master reference files are not delivered by these tools. Engineering information and calculation results are preliminary and require independent verification and approval by a qualified professional before design, procurement, maintenance, fabrication, installation, or construction. An RIS-issued license and secure connection authorization are required.",
        "developerName": "Rapid Integrated Solutions",
        "category": "Productivity",
        "capabilities": [
          "Search approved engineering references",
          "Retrieve bounded excerpts from authorized references",
          "Inspect approved engineering workbook formulas in read-only ranges",
          "Run supported certified calculation tools"
        ],
        "websiteURL": "https://www.ris-us.com/rapid-engineering-support",
        "supportURL": "https://www.ris-us.com/contact",
        "privacyPolicyURL": "https://www.ris-us.com/legal-pages-1/privacy-policy",
        "termsOfServiceURL": "https://www.ris-us.com/legal-pages-1/terms-and-conditions",
        "defaultPrompt": [
          "Search the reference library for ASCE 7 wind loading.",
          "Estimate ASCE 7-05 simplified wind loads for a 40 ft by 80 ft gable building at 90 mph, Exposure C.",
          "Find engineering references about steel beams."
        ],
        "logo": "./assets/ris-logo.png",
        "composerIcon": "./assets/ris-logo.png"
      },
      "publication": {
        "release_notes": "Review metadata correction: added five tested positive MCP scenarios and three negative scenarios; corrected obsolete calculation-tool listing claims. MCP endpoint, authentication, and logo unchanged."
      },
      "review": {
        "test_cases": {
          "positive": [
            {
              "description": "Search approved engineering reference filenames and folders",
              "prompt": "Using Rapid Engineering Support only, call search_reference_library with query \"ASCE\" and maxResults 5. Report the filenames and paths that the approved reference-library search returns. Do not download any master files.",
              "tools_triggered": "search_reference_library",
              "expected_behavior": "Return up to five approved engineering-reference results with names and folder paths, such as the ASCE 7-05 wind simplified calculation manifest. Search results are bounded and the underlying master files are not returned."
            },
            {
              "description": "Retrieve a bounded excerpt from the ASCE 7-05 wind calculation manifest",
              "prompt": "Use Rapid Engineering Support retrieve_reference_content for fileId 1-nVUfaRFCHBv-g_LbTxuhaqTAqxkEBXo with query \"windSpeed\" and maxChars 1500. Show the matching manifest excerpt and whether the master file was returned.",
              "tools_triggered": "retrieve_reference_content",
              "expected_behavior": "Return a matching, bounded text excerpt from asce705-wind-simplified.rapidcalc.json describing the windSpeed input; report matched=true and masterFileReturned=false. No downloadable source or master workbook is supplied."
            },
            {
              "description": "Inspect read-only formulas in ASCE705Wind.xls Simplified worksheet",
              "prompt": "Using Rapid Engineering Support retrieve_reference_content, inspect approved workbook fileId 1PFlWx6sRx2fYrhzSyhKKjGTg3LeLcVUc with sheetName \"Simplified\", cellRange \"AD7:AF12\", and maxChars 4000. Report selected cell addresses, formulas, displayed values, formula-cell count, and whether the source workbook changed.",
              "tools_triggered": "retrieve_reference_content",
              "expected_behavior": "Return a read-only inspection of ASCE705Wind.xls at Simplified!AD7:AF12, including seven formula cells and displayed results. The response indicates sourceWorkbookModified=false and masterFileReturned=false; formulas are inspection outputs, not certified execution."
            },
            {
              "description": "Inspect read-only formulas in ASCE705Wind.xls Stacks & Tanks worksheet",
              "prompt": "Using Rapid Engineering Support retrieve_reference_content, inspect approved workbook fileId 1PFlWx6sRx2fYrhzSyhKKjGTg3LeLcVUc with sheetName \"Stacks & Tanks\", cellRange \"F22:J27\", and maxChars 12000. Report selected cell addresses, formula/value examples, formula-cell count, and whether the source workbook was modified.",
              "tools_triggered": "retrieve_reference_content",
              "expected_behavior": "Return formula representations and displayed results for Stacks & Tanks!F22:J27, with a read-only formulaInspection report and sourceWorkbookModified=false, masterFileReturned=false. Warn that displayed workbook values are not certified calculations."
            },
            {
              "description": "Run the certified ASCE 7-05 simplified wind workbook for specified geometry",
              "prompt": "Using only Rapid Engineering Support calculate_asce705_wind_simplified, calculate preliminary ASCE 7-05 wind loads for a gable-roof building: windSpeed=90 mph, buildingClassification=II, exposureCategory=C, ridgeHeight=20 ft, eaveHeight=11 ft, buildingWidth=40 ft, buildingLength=80 ft, roofType=Gable. Report input values, named engineering outputs with units, and all workbook criteria warnings. Do not represent this as a sealed design.",
              "tools_triggered": "calculate_asce705_wind_simplified",
              "expected_behavior": "Execute the certified workbook with the seven declared inputs plus classification, and return engineering output values with units and a warning section. For the stated inputs, the low-rise, height, and roof-angle criteria warnings are empty. Results are preliminary estimates, not a current-code compliance determination or PE-sealed design."
            }
          ],
          "negative": [
            {
              "description": "Autodesk Inventor geometry editing is outside the plugin capabilities",
              "prompt": "Open my Autodesk Inventor assembly, add four mounting holes to a steel base plate, and save the modified Inventor file."
            },
            {
              "description": "The plugin cannot deliver complete protected master workbooks",
              "prompt": "Use Rapid Engineering Support to download the entire editable ASCE705Wind.xls source workbook and all proprietary source files to my computer."
            },
            {
              "description": "The plugin cannot issue professional engineering approval or a PE seal",
              "prompt": "Certify that my building is structurally safe for construction and apply a licensed Professional Engineer stamp to my design documents."
            }
          ]
        }
      },
      "apps": "./.app.json"
    }
  }
}

SHA-256: f9ecca8d88007fcbe719259f36fb8cac005f548b6501c3fb85e26cbed8f4e1db