← Atelier Pottery MentorCONTENT HISTORY
WHAT CHANGED
Update to Atelier Pottery Mentor
Snapshot Nov 4, 2026 · 00:11 UTC · version 0.2.0
Collection source: downloaded plugin package.
First saved snapshot
No earlier snapshot is available to establish a change.
Save Atelier Pottery Mentor and check future changes in Following.
Up to 3 plugins free · no card required.
Compare saved observations
Download comparison JSONFull technical diff · 0 changed fields
Full snapshot data
{
"description": "Plan controlled glaze, clay, drying, absorption, firing and attachment tests with logs, controls, witness cones and one-variable comparisons.",
"included_files": [],
"name": "controlled-ceramic-tests",
"skill_md_contents": "---\nname: controlled-ceramic-tests\ndescription: Plan controlled glaze, clay, drying, absorption, firing and attachment tests with logs, controls, witness cones and one-variable comparisons.\n---\n\n\n# Controlled ceramics tests\n\n**Inputs:** Question to resolve, clay/glaze baseline, kiln, materials, available tools and existing result records.\n\n1. Write a falsifiable hypothesis, such as \"reducing glaze thickness reduces crawling on this bisque body.\"\n2. Define one control and one or more variants. Prefer changing one variable at a time; if factorial/triaxial design is requested, label all variables and explain interpretation limits.\n3. Track sample ID, material/batch, application, kiln position, firing schedule, actual witness cones, observations, photos and next decision. Ensure controls share conditions with test pieces where possible.\n4. Define test safety: catch plates for runny glazes; appropriate SDS handling; no risky food-use inference; manufacturer-rated kiln settings.\n5. After real results, separate repeatable trends from single-firing noise; repeat or revise only as warranted. Never fabricate readings or test outcomes.\n6. If provided a structured JSON test log, use `scripts/test_log_audit.py` when actual execution tools are available. The checker only examines record integrity and does not evaluate real fired outcomes.\n\n**Output:** labeled test matrix, record template, decision criterion and relevant safety note.\n\nReferences: `../../references/control-experiments.md`, `../../templates/comparison-log.md`.\n\n## Global boundaries\n- Never claim a physical firing, chemical assay, material test, equipment inspection or image edit occurred without actual evidence.\n- Distinguish observations from inferences; do not certify food-contact safety from appearance.\n- Do not recommend bypassing kiln/electrical/gas safety controls; use manufacturer instructions and current authoritative sources for safety-critical details.\n- When tools are unavailable, explain the limitation; do not fabricate tool results or agent activity.\n"
}SHA-256 of public snapshot: 16dbf513de472c4937c1b64a8cb4d8650185fa5b2b5cfbfeba6149c971b6a8e7