← RungstoneCONTENT HISTORY

Update to Rungstone

Snapshot Nov 10, 2026 · 12:09 UTC · version 0.1.8

WHAT CHANGED

Product listing or positioning changed

Full description — Now says: check, diff, translate, verify and dependency-map PLC code across Rockwell, Siemens, CODESYS, Beckhoff, OpenPLC and IEC 61499 (4diac); lock-in reports for...

Observed in the public listing; claims come from the publisher.

Save Rungstone and check future changes in Following.

Up to 3 plugins free · no card required.

All fields and original values.

Full description

Before

Nov 3, 2026 · 06:12 UTC

translate, verify and dependency-map PLC code across Rockwell, Siemens, CODESYS and Beckhoff;

After

Nov 10, 2026 · 12:09 UTC

check, diff, translate, verify and dependency-map PLC code across Rockwell, Siemens, CODESYS, Beckhoff, OpenPLC and IEC 61499 (4diac); lock-in reports for CODESYS/TwinCAT projects; unit tests for function blocks;

Declared skills

Before

Nov 3, 2026 · 06:12 UTC

[{"description":"Understand, retarget, migrate, verify and clean up HMI and SCADA projects alongside the PLC code they talk to. Use this skill whenever the user mentions an HMI, SCADA, Ignition, FactoryTalk View, PanelView, WinCC, Wonder...

After

Nov 10, 2026 · 12:09 UTC

[{"description":"Understand, retarget, migrate, verify and clean up HMI and SCADA projects alongside the PLC code they talk to. Use this skill whenever the user mentions an HMI, SCADA, Ignition, FactoryTalk View, PanelView, WinCC, Wonder...

Composer icon url

Before

Nov 3, 2026 · 06:12 UTC

https://files.openai.com/content?id=file_000000008f78820db95d34fb3fff7015

After

Nov 10, 2026 · 12:09 UTC

https://files.openai.com/content?id=file_00000000f2a0820db1f905a098386266

Default prompt

Before

Nov 3, 2026 · 06:12 UTC

Explain what this L5X does, rung by rung

After

Nov 10, 2026 · 12:09 UTC

Not present

Compare saved observations

Download comparison JSON
Full technical diff · 10 changed fields

changed /release/description

BEFORE
"Offline, read-only toolkit for controls engineers: understand, translate, verify and dependency-map PLC code across Rockwell, Siemens, CODESYS and Beckhoff; extend to HMI/SCADA screens, tags and alarms; troubleshoot stops from exported historian data. Safety-rated logic is always excluded; simulation results are labelled simulated, not hardware-tested."
AFTER
"Offline, read-only toolkit for controls engineers: understand, check, diff, translate, verify and dependency-map PLC code across Rockwell, Siemens, CODESYS, Beckhoff, OpenPLC and IEC 61499 (4diac); lock-in reports for CODESYS/TwinCAT projects; unit tests for function blocks; extend to HMI/SCADA screens, tags and alarms; troubleshoot stops from exported historian data. Safety-rated logic is always excluded; simulation results are labelled simulated, not hardware-tested."

changed /release/id

BEFORE
"pluginrel_25c553f9dd348191913c298959bcc0e3"
AFTER
"pluginrel_c8350511913481918fabd190c4f4656c"

changed /release/interface/composer_icon_url

BEFORE
"https://files.openai.com/content?id=file_000000008f78820db95d34fb3fff7015"
AFTER
"https://files.openai.com/content?id=file_00000000f2a0820db1f905a098386266"

changed /release/interface/default_prompt

BEFORE
"Explain what this L5X does, rung by rung"
AFTER
null

changed /release/interface/default_prompts

BEFORE
[
  "Explain what this L5X does, rung by rung",
  "Translate this SLC 500 ladder to Siemens S7-1500 SCL",
  "Why did the pump trip? The historian and alarm exports are in this folder"
]
AFTER
null

changed /release/interface/logo_url

BEFORE
"https://files.openai.com/content?id=file_0000000082d8820d911272af486ee751"
AFTER
"https://files.openai.com/content?id=file_000000003920820d89f1e28157d0a917"

changed /release/interface/screenshot_urls

BEFORE
[
  "https://files.openai.com/content?id=file_00000000984c820d9ab9db0d02af39f5",
  "https://files.openai.com/content?id=file_000000001680820d878c3a2935fe54e6"
]
AFTER
[]

changed /release/keywords

BEFORE
[
  "plc",
  "ladder-logic",
  "structured-text",
  "rockwell",
  "siemens",
  "tia-portal",
  "codesys",
  "twincat",
  "plcopen",
  "scada",
  "hmi",
  "industrial-automation",
  "migration",
  "alarm-management"
]
AFTER
[
  "plc",
  "ladder-logic",
  "structured-text",
  "rockwell",
  "siemens",
  "tia-portal",
  "codesys",
  "twincat",
  "plcopen",
  "scada",
  "hmi",
  "industrial-automation",
  "migration",
  "alarm-management",
  "openplc",
  "iec-61499",
  "4diac",
  "static-analysis",
  "unit-testing"
]

changed /release/skills

BEFORE
[
  {
    "description": "Understand, retarget, migrate, verify and clean up HMI and SCADA projects alongside the PLC code they talk to. Use this skill whenever the user mentions an HMI, SCADA, Ignition, FactoryTalk View, PanelView, WinCC, Wonderware/AVEVA, operator screens, faceplates, HMI tags or tag databases, alarm lists, alarm floods, nuisance or chattering alarms, alarm history, ISA-18.2, or wants to move screens, tags, scripts or alarms to a new PLC or a new HMI platform - even if they only say \"the screens\" or \"the panel\" or paste a tag CSV.",
    "interface": {
      "brand_color": null,
      "default_prompt": null,
      "display_name": "rungstone-hmi-scada",
      "icon_large_url": null,
      "icon_small_url": null,
      "iconography": "hierarchy",
      "short_description": "Understand, retarget, migrate, verify and clean up HMI and SCADA projects alongside the PLC code they talk to. Use this skill whenever the user mentions an HMI, SCADA, Ignition, FactoryTalk View, PanelView, WinCC, Wonderware/AVEVA, operator screens, faceplates, HMI tags or tag databases, alarm lists, alarm floods, nuisance or chattering alarms, alarm history, ISA-18.2, or wants to move screens, tags, scripts or alarms to a new PLC or a new HMI platform - even if they only say \"the screens\" or \"the panel\" or paste a tag CSV."
    },
    "name": "rungstone-hmi-scada",
    "plugin_release_skill_id": "pluginrsk_6ae8ebd693788191936b8050f4b82bfb"
  },
  {
    "description": "Offline operations troubleshooting for industrial plants from exported data - why a line, machine, pump, conveyor or compressor stopped or tripped, downtime and stop causes, alarm and event logs, historian trends, first-out analysis, shift reports, MTBF/MTTR/availability, recurring faults. Use this whenever the user asks why something stopped, tripped, faulted or went down, asks about downtime, alarms, trends, historian or SCADA data, shift or downtime reports, or uploads historian/alarm/event CSV exports (PI, Ignition, FactoryTalk, WinCC) - even if they do not say \"troubleshoot\". Ties the data back to the PLC logic that caused the stop. Part of Rungstone; offline only, no live monitoring.",
    "interface": {
      "brand_color": null,
      "default_prompt": null,
      "display_name": "rungstone-ops",
      "icon_large_url": null,
      "icon_small_url": null,
      "iconography": "radar",
      "short_description": "Offline operations troubleshooting for industrial plants from exported data - why a line, machine, pump, conveyor or compressor stopped or tripped, downtime and stop causes, alarm and event logs, historian trends, first-out analysis, shift reports, MTBF/MTTR/availability, recurring faults. Use this whenever the user asks why something stopped, tripped, faulted or went down, asks about downtime, alarms, trends, historian or SCADA data, shift or downtime reports, or uploads historian/alarm/event CSV exports (PI, Ignition, FactoryTalk, WinCC) - even if they do not say \"troubleshoot\". Ties the data back to the PLC logic that caused the stop. Part of Rungstone; offline only, no live monitoring."
    },
    "name": "rungstone-ops",
    "plugin_release_skill_id": "pluginrsk_6ae8ebd6b5048191a477666687506b93"
  },
  {
    "description": "Understand, translate, verify, and dependency-map industrial PLC code across vendors (Rockwell/Allen-Bradley Studio 5000, RSLogix 5000/500, L5X, SLC 500, PLC-5, Siemens TIA Portal SCL/S7/SimaticML, CODESYS, Beckhoff TwinCAT, PLCopen XML, IEC 61131-3 Structured Text, IEC 61499 / Eclipse 4diac, ladder logic). Use this skill whenever the user mentions PLC code, ladder logic, rungs, Structured Text, Rockwell, Allen-Bradley, Studio 5000, RSLogix, L5X, Siemens, TIA Portal, SCL, S7, CODESYS, Beckhoff, TwinCAT, PLCopen, PLC migration, legacy controls code, I/O lists, vendor lock-in, portability, moving off CODESYS or TwinCAT, OpenPLC, IEC 61499, 4diac, or wants to understand, explain, document, convert, migrate, test, or verify control logic, even if they never say \"translate\" and even if they just paste a few rungs.",
    "interface": {
      "brand_color": null,
      "default_prompt": null,
      "display_name": "rungstone-plc",
      "icon_large_url": null,
      "icon_small_url": null,
      "iconography": "code",
      "short_description": "Understand, translate, verify, and dependency-map industrial PLC code across vendors (Rockwell/Allen-Bradley Studio 5000, RSLogix 5000/500, L5X, SLC 500, PLC-5, Siemens TIA Portal SCL/S7/SimaticML, CODESYS, Beckhoff TwinCAT, PLCopen XML, IEC 61131-3 Structured Text, IEC 61499 / Eclipse 4diac, ladder logic). Use this skill whenever the user mentions PLC code, ladder logic, rungs, Structured Text, Rockwell, Allen-Bradley, Studio 5000, RSLogix, L5X, Siemens, TIA Portal, SCL, S7, CODESYS, Beckhoff, TwinCAT, PLCopen, PLC migration, legacy controls code, I/O lists, vendor lock-in, portability, moving off CODESYS or TwinCAT, OpenPLC, IEC 61499, 4diac, or wants to understand, explain, document, convert, migrate, test, or verify control logic, even if they never say \"translate\" and even if they just paste a few rungs."
    },
    "name": "rungstone-plc",
    "plugin_release_skill_id": "pluginrsk_6ae8ebd7205c8191b6d7406798d78147"
  }
]
AFTER
[
  {
    "description": "Understand, retarget, migrate, verify and clean up HMI and SCADA projects alongside the PLC code they talk to. Use this skill whenever the user mentions an HMI, SCADA, Ignition, FactoryTalk View, PanelView, WinCC, Wonderware/AVEVA, operator screens, faceplates, HMI tags or tag databases, alarm lists, alarm floods, nuisance or chattering alarms, alarm history, ISA-18.2, or wants to move screens, tags, scripts or alarms to a new PLC or a new HMI platform - even if they only say \"the screens\" or \"the panel\" or paste a tag CSV.",
    "interface": {
      "brand_color": null,
      "default_prompt": null,
      "display_name": "rungstone-hmi-scada",
      "icon_large_url": null,
      "icon_small_url": null,
      "iconography": "code",
      "short_description": "Understand, retarget, migrate, verify and clean up HMI and SCADA projects alongside the PLC code they talk to. Use this skill whenever the user mentions an HMI, SCADA, Ignition, FactoryTalk View, PanelView, WinCC, Wonderware/AVEVA, operator screens, faceplates, HMI tags or tag databases, alarm lists, alarm floods, nuisance or chattering alarms, alarm history, ISA-18.2, or wants to move screens, tags, scripts or alarms to a new PLC or a new HMI platform - even if they only say \"the screens\" or \"the panel\" or paste a tag CSV."
    },
    "name": "rungstone-hmi-scada",
    "plugin_release_skill_id": "pluginrsk_6aecd93ef45481919617343813a2e2a7"
  },
  {
    "description": "Offline operations troubleshooting for industrial plants from exported data - why a line, machine, pump, conveyor or compressor stopped or tripped, downtime and stop causes, alarm and event logs, historian trends, first-out analysis, shift reports, MTBF/MTTR/availability, recurring faults. Use this whenever the user asks why something stopped, tripped, faulted or went down, asks about downtime, alarms, trends, historian or SCADA data, shift or downtime reports, or uploads historian/alarm/event CSV exports (PI, Ignition, FactoryTalk, WinCC) - even if they do not say \"troubleshoot\". Ties the data back to the PLC logic that caused the stop. Part of Rungstone; offline only, no live monitoring.",
    "interface": {
      "brand_color": null,
      "default_prompt": null,
      "display_name": "rungstone-ops",
      "icon_large_url": null,
      "icon_small_url": null,
      "iconography": "radar",
      "short_description": "Offline operations troubleshooting for industrial plants from exported data - why a line, machine, pump, conveyor or compressor stopped or tripped, downtime and stop causes, alarm and event logs, historian trends, first-out analysis, shift reports, MTBF/MTTR/availability, recurring faults. Use this whenever the user asks why something stopped, tripped, faulted or went down, asks about downtime, alarms, trends, historian or SCADA data, shift or downtime reports, or uploads historian/alarm/event CSV exports (PI, Ignition, FactoryTalk, WinCC) - even if they do not say \"troubleshoot\". Ties the data back to the PLC logic that caused the stop. Part of Rungstone; offline only, no live monitoring."
    },
    "name": "rungstone-ops",
    "plugin_release_skill_id": "pluginrsk_6aecd93efd2c8191a34f00b64548f56d"
  },
  {
    "description": "Understand, translate, verify, and dependency-map industrial PLC code across vendors (Rockwell/Allen-Bradley Studio 5000, RSLogix 5000/500, L5X, SLC 500, PLC-5, Siemens TIA Portal SCL/S7/SimaticML, CODESYS, Beckhoff TwinCAT, PLCopen XML, IEC 61131-3 Structured Text, IEC 61499 / Eclipse 4diac, ladder logic). Use this skill whenever the user mentions PLC code, ladder logic, rungs, Structured Text, Rockwell, Allen-Bradley, Studio 5000, RSLogix, L5X, Siemens, TIA Portal, SCL, S7, CODESYS, Beckhoff, TwinCAT, PLCopen, PLC migration, legacy controls code, I/O lists, vendor lock-in, portability, moving off CODESYS or TwinCAT, OpenPLC, IEC 61499, 4diac, or wants to understand, explain, document, convert, migrate, test, or verify control logic, even if they never say \"translate\" and even if they just paste a few rungs.",
    "interface": {
      "brand_color": null,
      "default_prompt": null,
      "display_name": "rungstone-plc",
      "icon_large_url": null,
      "icon_small_url": null,
      "iconography": "code",
      "short_description": "Understand, translate, verify, and dependency-map industrial PLC code across vendors (Rockwell/Allen-Bradley Studio 5000, RSLogix 5000/500, L5X, SLC 500, PLC-5, Siemens TIA Portal SCL/S7/SimaticML, CODESYS, Beckhoff TwinCAT, PLCopen XML, IEC 61131-3 Structured Text, IEC 61499 / Eclipse 4diac, ladder logic). Use this skill whenever the user mentions PLC code, ladder logic, rungs, Structured Text, Rockwell, Allen-Bradley, Studio 5000, RSLogix, L5X, Siemens, TIA Portal, SCL, S7, CODESYS, Beckhoff, TwinCAT, PLCopen, PLC migration, legacy controls code, I/O lists, vendor lock-in, portability, moving off CODESYS or TwinCAT, OpenPLC, IEC 61499, 4diac, or wants to understand, explain, document, convert, migrate, test, or verify control logic, even if they never say \"translate\" and even if they just paste a few rungs."
    },
    "name": "rungstone-plc",
    "plugin_release_skill_id": "pluginrsk_6aecd93ef3408191a550ad1d0a84fca2"
  }
]

changed /release/version

BEFORE
"0.1.7"
AFTER
"0.1.8"
Full snapshot data
{
  "canonical_app_id": null,
  "connector_id": null,
  "created_at": "2026-10-29T18:10:35.207377Z",
  "discoverability": "LISTED",
  "id": "plugins_6ae38208de4c819197dd42fdda98dbc6",
  "is_template": false,
  "is_template_instance": false,
  "is_v2_template": false,
  "name": "rungstone",
  "release": {
    "app_ids": [],
    "app_manifest": null,
    "app_templates": [],
    "description": "Offline, read-only toolkit for controls engineers: understand, check, diff, translate, verify and dependency-map PLC code across Rockwell, Siemens, CODESYS, Beckhoff, OpenPLC and IEC 61499 (4diac); lock-in reports for CODESYS/TwinCAT projects; unit tests for function blocks; extend to HMI/SCADA screens, tags and alarms; troubleshoot stops from exported historian data. Safety-rated logic is always excluded; simulation results are labelled simulated, not hardware-tested.",
    "display_name": "Rungstone",
    "id": "pluginrel_c8350511913481918fabd190c4f4656c",
    "interface": {
      "brand_color": "#F5A524",
      "capabilities": [
        "Read",
        "Write"
      ],
      "category": "Developer Tools",
      "composer_icon_dark_url": null,
      "composer_icon_url": "https://files.openai.com/content?id=file_00000000f2a0820db1f905a098386266",
      "default_prompt": null,
      "default_prompts": null,
      "developer_name": "Arun Venkatadri",
      "logo_url": "https://files.openai.com/content?id=file_000000003920820d89f1e28157d0a917",
      "logo_url_dark": null,
      "long_description": "Rungstone helps industrial controls engineers work with PLC, HMI/SCADA and historian exports.\n\n- Understand PLC code: a plain-English summary, the machine sequence by rung, and a signal table where every meaning is labelled confirmed, from comment, from I/O map, inferred or unknown.\n- Translate between Rockwell Logix, SLC 500, Siemens S7-1500 SCL, IEC 61131-3 Structured Text, OpenPLC / Beremiz and IEC 61499 (Eclipse 4diac), with a mapping table and a ranked review queue the engineer approves before export.\n- Verify translations in a scan-cycle simulator (results are labelled simulated, not hardware-tested).\n- Lock-in report for CODESYS and TwinCAT projects: what ties the code to its platform, rated per target with rough hours.\n- Check (static analysis for likely bugs), diff two exports of the same project in plain English, and generate unit tests (CfUnit, TcUnit or plain IEC) from the code's current behaviour.\n- Map readers, writers and conflicts across PLC and HMI/SCADA, retarget HMI tags, and clean up alarms.\n- Find why a line or pump stopped from historian and alarm exports, and cite the PLC rung that caused it.\n\nRead-only by design: it never connects to or writes to a controller, excludes safety-rated logic with a visible notice, and never opens source-protected code. Not for use on a production system without review and testing by a qualified engineer. Provided as is, without warranty.",
      "plugin_category_id": "developer tools",
      "privacy_policy_url": "https://github.com/arunvenkatadri/rungstone/blob/main/PRIVACY.md",
      "screenshot_urls": [],
      "short_description": "PLC, HMI and trip analysis",
      "terms_of_service_url": "https://github.com/arunvenkatadri/rungstone/blob/main/LICENSE",
      "website_url": "https://github.com/arunvenkatadri/rungstone"
    },
    "keywords": [
      "plc",
      "ladder-logic",
      "structured-text",
      "rockwell",
      "siemens",
      "tia-portal",
      "codesys",
      "twincat",
      "plcopen",
      "scada",
      "hmi",
      "industrial-automation",
      "migration",
      "alarm-management",
      "openplc",
      "iec-61499",
      "4diac",
      "static-analysis",
      "unit-testing"
    ],
    "mcp_servers": [],
    "onboarding_skill_name": null,
    "requires_local_executor": false,
    "skills": [
      {
        "description": "Understand, retarget, migrate, verify and clean up HMI and SCADA projects alongside the PLC code they talk to. Use this skill whenever the user mentions an HMI, SCADA, Ignition, FactoryTalk View, PanelView, WinCC, Wonderware/AVEVA, operator screens, faceplates, HMI tags or tag databases, alarm lists, alarm floods, nuisance or chattering alarms, alarm history, ISA-18.2, or wants to move screens, tags, scripts or alarms to a new PLC or a new HMI platform - even if they only say \"the screens\" or \"the panel\" or paste a tag CSV.",
        "interface": {
          "brand_color": null,
          "default_prompt": null,
          "display_name": "rungstone-hmi-scada",
          "icon_large_url": null,
          "icon_small_url": null,
          "iconography": "code",
          "short_description": "Understand, retarget, migrate, verify and clean up HMI and SCADA projects alongside the PLC code they talk to. Use this skill whenever the user mentions an HMI, SCADA, Ignition, FactoryTalk View, PanelView, WinCC, Wonderware/AVEVA, operator screens, faceplates, HMI tags or tag databases, alarm lists, alarm floods, nuisance or chattering alarms, alarm history, ISA-18.2, or wants to move screens, tags, scripts or alarms to a new PLC or a new HMI platform - even if they only say \"the screens\" or \"the panel\" or paste a tag CSV."
        },
        "name": "rungstone-hmi-scada",
        "plugin_release_skill_id": "pluginrsk_6aecd93ef45481919617343813a2e2a7"
      },
      {
        "description": "Offline operations troubleshooting for industrial plants from exported data - why a line, machine, pump, conveyor or compressor stopped or tripped, downtime and stop causes, alarm and event logs, historian trends, first-out analysis, shift reports, MTBF/MTTR/availability, recurring faults. Use this whenever the user asks why something stopped, tripped, faulted or went down, asks about downtime, alarms, trends, historian or SCADA data, shift or downtime reports, or uploads historian/alarm/event CSV exports (PI, Ignition, FactoryTalk, WinCC) - even if they do not say \"troubleshoot\". Ties the data back to the PLC logic that caused the stop. Part of Rungstone; offline only, no live monitoring.",
        "interface": {
          "brand_color": null,
          "default_prompt": null,
          "display_name": "rungstone-ops",
          "icon_large_url": null,
          "icon_small_url": null,
          "iconography": "radar",
          "short_description": "Offline operations troubleshooting for industrial plants from exported data - why a line, machine, pump, conveyor or compressor stopped or tripped, downtime and stop causes, alarm and event logs, historian trends, first-out analysis, shift reports, MTBF/MTTR/availability, recurring faults. Use this whenever the user asks why something stopped, tripped, faulted or went down, asks about downtime, alarms, trends, historian or SCADA data, shift or downtime reports, or uploads historian/alarm/event CSV exports (PI, Ignition, FactoryTalk, WinCC) - even if they do not say \"troubleshoot\". Ties the data back to the PLC logic that caused the stop. Part of Rungstone; offline only, no live monitoring."
        },
        "name": "rungstone-ops",
        "plugin_release_skill_id": "pluginrsk_6aecd93efd2c8191a34f00b64548f56d"
      },
      {
        "description": "Understand, translate, verify, and dependency-map industrial PLC code across vendors (Rockwell/Allen-Bradley Studio 5000, RSLogix 5000/500, L5X, SLC 500, PLC-5, Siemens TIA Portal SCL/S7/SimaticML, CODESYS, Beckhoff TwinCAT, PLCopen XML, IEC 61131-3 Structured Text, IEC 61499 / Eclipse 4diac, ladder logic). Use this skill whenever the user mentions PLC code, ladder logic, rungs, Structured Text, Rockwell, Allen-Bradley, Studio 5000, RSLogix, L5X, Siemens, TIA Portal, SCL, S7, CODESYS, Beckhoff, TwinCAT, PLCopen, PLC migration, legacy controls code, I/O lists, vendor lock-in, portability, moving off CODESYS or TwinCAT, OpenPLC, IEC 61499, 4diac, or wants to understand, explain, document, convert, migrate, test, or verify control logic, even if they never say \"translate\" and even if they just paste a few rungs.",
        "interface": {
          "brand_color": null,
          "default_prompt": null,
          "display_name": "rungstone-plc",
          "icon_large_url": null,
          "icon_small_url": null,
          "iconography": "code",
          "short_description": "Understand, translate, verify, and dependency-map industrial PLC code across vendors (Rockwell/Allen-Bradley Studio 5000, RSLogix 5000/500, L5X, SLC 500, PLC-5, Siemens TIA Portal SCL/S7/SimaticML, CODESYS, Beckhoff TwinCAT, PLCopen XML, IEC 61131-3 Structured Text, IEC 61499 / Eclipse 4diac, ladder logic). Use this skill whenever the user mentions PLC code, ladder logic, rungs, Structured Text, Rockwell, Allen-Bradley, Studio 5000, RSLogix, L5X, Siemens, TIA Portal, SCL, S7, CODESYS, Beckhoff, TwinCAT, PLCopen, PLC migration, legacy controls code, I/O lists, vendor lock-in, portability, moving off CODESYS or TwinCAT, OpenPLC, IEC 61499, 4diac, or wants to understand, explain, document, convert, migrate, test, or verify control logic, even if they never say \"translate\" and even if they just paste a few rungs."
        },
        "name": "rungstone-plc",
        "plugin_release_skill_id": "pluginrsk_6aecd93ef3408191a550ad1d0a84fca2"
      }
    ],
    "version": "0.1.8"
  },
  "scope": "GLOBAL",
  "share_url": "https://chatgpt.com/plugins/plugins_6ae38208de4c819197dd42fdda98dbc6?open_in_app",
  "status": "ENABLED"
}

SHA-256 of public snapshot: 5e546798150df6e2e381569e50e548c94d81d16a0ed5b5a4a343a1714b2904fc