← Files EW Golden Baseline ModelARCHIVED FILE
skills/baseline-analysis-builder/references/power-timeseries-example.md
3.41 KB · Oct 3, 2026 · 06:36 UTC
# 功率時序算法範例
這是感應爐或其他工業設備功率曲線的參考,不是固定配方。建立實際 Skill 時,必須依設備階段、採樣間隔、額定範圍、事件錨點及資料品質調整。
## 適用意圖
- 比較實際功率曲線與黃金基線圖層。
- 在人工、PLC、批次或 Tagger 確認起點後才開始對齊。
- 歷史事件評估數值、時長、形狀、斜率、面積、穩定度及缺失。
- 即時事件只啟動不依賴終點的算法,事件完成後補算完整結果。
## 參考 Manifest
```json
{
"schema_version": "golden-baseline-declarative-pipeline/v1",
"pipeline_id": "industrial_power_profile",
"pipeline_version": "1.0.0",
"engine_api_version": "deterministic-feature-api/v1",
"signal_roles": [
{
"role": "power",
"aliases": ["power", "功率", "有功功率"],
"compatible_units": ["W", "kW", "MW"],
"required": true
}
],
"execution_profiles": {
"historical_closed_event": [
"time_alignment",
"missing_deviation",
"value_deviation",
"time_deviation",
"waveform_deviation",
"slope_deviation",
"area_deviation",
"stability_deviation"
],
"realtime_open_event": [
"time_alignment",
"missing_deviation",
"value_deviation",
"waveform_deviation",
"slope_deviation",
"stability_deviation"
]
},
"quality_gates": {
"minimum_completeness": 0.9,
"maximum_missing_rate": 0.2,
"minimum_points": 7,
"maximum_gap_multiplier": 6.0,
"require_monotonic_timestamps": true,
"require_compatible_units": true,
"require_confirmed_event_start": true
},
"threshold_overrides": {},
"fixtures": [
{
"fixture_id": "power_normal",
"category": "normal",
"execution_mode": "historical_closed_event",
"unit": "kW",
"sample_interval_ms": 10000,
"baseline_values": [0, 100, 300, 500, 300, 100, 0],
"observed_values": [0, 100, 300, 500, 300, 100, 0],
"data_completeness": 1.0,
"expected_status": "normal"
},
{
"fixture_id": "power_abnormal_high",
"category": "abnormal",
"execution_mode": "historical_closed_event",
"unit": "kW",
"sample_interval_ms": 10000,
"baseline_values": [0, 100, 300, 500, 300, 100, 0],
"observed_values": [25, 125, 325, 525, 325, 125, 25],
"data_completeness": 1.0,
"expected_status": "abnormal"
},
{
"fixture_id": "power_insufficient",
"category": "insufficient_data",
"execution_mode": "historical_closed_event",
"unit": "kW",
"sample_interval_ms": 10000,
"baseline_values": [0, 100, 300, 500, 300, 100, 0],
"observed_values": [0, 100],
"data_completeness": 0.28,
"expected_status": "insufficient_data"
}
],
"proposed_algorithms": []
}
```
## 改用其他工藝時
1. 把 `power` 改成實際訊號角色,例如溫度、壓力、流量、振動或速度。
2. 改用實際相容單位,不得混用無法換算的量綱。
3. 依事件長度及採樣間隔設定最少點數。
4. 只選與工藝偏差有關的算法;平台穩定度不適用於持續升降段,面積偏差也不是所有訊號都有物理意義。
5. 保留三類固定案例,並讓異常案例對應使用者真正關心的偏差。
6. 新需求超出允許算法時列入 `proposed_algorithms`,交由後端及管理員建立新版本,不能假裝已經支援。
SHA-256: 2d181158c7d91588e4b3a55f2462c3a1ef494e303ec3e7087c0de7e65ad5e8f2