← HomeLoadCONTENT HISTORY
WHAT CHANGED
Update to HomeLoad
Snapshot Nov 18, 2026 · 06:19 UTC · version 1.0.4
Collection source: downloaded plugin package.
First saved snapshot
No earlier snapshot is available to establish a change.
Save HomeLoad and check future changes in Following.
Up to 3 plugins free · no card required.
Compare saved observations
Download comparison JSONFull technical diff · 0 changed fields
Full snapshot data
{
"description": "Size a home's air conditioner, heat pump or furnace, size a portable or standby generator, or check whether an existing electrical panel can take a new load such as an EV charger or heat pump, for houses in the US by city or ZIP code. Use when a user asks what size system their house needs, whether a quoted size is right, or whether their panel has room.",
"included_files": [],
"name": "homeload",
"skill_md_contents": "---\nname: homeload\ndescription: Size a home's air conditioner, heat pump or furnace, size a portable or standby generator, or check whether an existing electrical panel can take a new load such as an EV charger or heat pump, for houses in the US by city or ZIP code. Use when a user asks what size system their house needs, whether a quoted size is right, or whether their panel has room.\n---\n\n# HomeLoad workflow\n\nUse the connected HomeLoad tools whenever the task is sizing residential HVAC, a generator, or\nelectrical-panel capacity for a house in the United States.\n\n## Tools\n- `size_hvac` — cooling and heating load and the Manual S tonnage range from ZIP, square feet\n and construction. Needs conditioned square feet and where the house is. A city and state is enough:\n pick a residential ZIP code in that city rather than asking, and name the county the result used. Never use a place\n the user has not stated, and never ask for a street address.\n- `size_generator` — running and starting watts and the generator class from a list of load ids\n (plus custom loads with nameplate watts). Ask which appliances matter before listing a whole house.\n- `panel_headroom` — NEC 220.83 calculation for an existing service: ZIP, square feet, panel\n rating, existing 240 V appliances, and what is being added. Set `strip_kw` when a heat pump\n with electric auxiliary heat is added.\n\n## Behaviour\n- Every result is a range or a calculated figure with its inputs; present it as an estimate to\n confirm with a contractor's Manual J or a licensed electrician. Keep the tool's note; do not\n raise the certainty.\n- The card shows the range, a scale with the Manual S band, the assumptions, how the size\n moves if the insulation differs (`sensitivity`), what the figures were checked against (`basis`)\n and a button that opens an installer or electrician sheet. Write three sentences: the range; the one assumption\n that moves it most, taken from `sensitivity`; that a contractor's Manual J (or a licensed\n electrician) confirms it. Do not repeat the card's table or basis, and do not paste the link\n unless the card fails to load.\n- When the user is checking a contractor's number or an installed unit (\"they said 4 tons\"), pass it\n as `quoted_tons`, ask the year built and the window type before calling if they are not given, and\n lead with the verdict in `quote_text`. A \"near\" verdict is not a finding against the contractor.\n- When the user asks whether a generator they have will run the loads, pass its running rating as\n `have_kw` in kW (7.5 for 7,500 W), and `have_starting_kw` if known. An advertised peak is not the\n running rating: ask if unsure.\n- `size_hvac` gives a heat pump's output at the design temperature and the backup it leaves\n (`heat_pump_text`). If the user then asks about the panel, pass `backup_strip_kw` as `strip_kw`.\n- Do not recommend brands or models, quote prices, or advise on financing.\n- Do not use the tools for commercial buildings, single rooms, RVs, job sites, subpanels or\n three-phase services, or for homes outside the 50 US states and DC.\n- If a tool reports an unknown ZIP code you picked, try a nearby residential ZIP. If the user typed it, say it was not\n found and which ZIP you used instead; if it reports invalid\n input, relay the message and ask for the corrected value.\n\nIf the tools are unavailable, say that the HomeLoad sizing service could not be reached. Do not\nfabricate a HomeLoad result.\n"
}SHA-256 of public snapshot: c4e06dfb0b41bea579eaab281e6aff7d071df0487a7e9134d29a453109b183ca